Power Supply/Chargers
Installation Guide
Models Include:
eFlow104N/eFlow104NX
- 10 amp @ 24VDC
eFlow104N8/ eFlow104N8D/
eFlow104NX8 eFlow104NX8D
- 10 amp @ 24VDC - 10 amp @ 24VDC
- Eight (8) Fused Outputs - Eight (8) PTC Outputs
eFlow104N16/ eFlow104N16D/
eFlow104NX16 eFlow104NX16D
- 10 amp @ 24VDC - 10 amp @ 24VDC
- Sixteen (16) Fused Outputs - Sixteen (16) PTC Outputs
Rev. 104NRP052213 More than just power.™
Installing Company: _____________________ Service Rep. Name: __________________________________________
Address: ________________________________________________________ Phone #: _________________________
Altronix Corp.
140 58th St. Brooklyn, NY
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - Installation Guide

Power Supply/ChargersInstallation GuideModels Include:eFlow104N/eFlow104NX- 10 amp @ 24VDCeFlow104N8/ eFlow104N8D/eFlow104NX8 eFlow104NX8D- 10 amp @ 2

Página 2

- 10 - eFlow104N SeriesNEC Power-Limited Wiring Requirements for eFlow104NX Models:Power-limited and non power-limited circuit wiring must remain sep

Página 3

eFlow104N Series - 11 -Enclosure Dimensions (BC300) (approximate H x W x D):eFlow104N, eFlow104N8, eFlow104N8D, eFlow104N16, eFlow104N16D13.5” x 13”

Página 4 - - 4 - eFlow104N Series

- 12 - eFlow104N Series1.5”(38.1mm)1.5”(38.1mm)1.5”(38.1mm)5.0”(127.0mm)5.0”(127.0mm)1.5”(38.1mm)2.0”(50.8mm)2.0”(50.8mm)1.75”(44.45mm)1.75”(44.45mm)

Página 5 - Power Distribution Module

eFlow104N Series - 13 -Appendix A - UL Listed Compatible DevicesA.1 Four (4) Wire Smoke DetectorsTable A-1 below lists four (4) wire smoke detectors

Página 6 - Power Distribution Module(s):

- 14 - eFlow104N SeriesNotes:

Página 7 - --- DC +

eFlow104N Series - 15 -Notes:Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice.1

Página 8 - - 8 - eFlow104N Series

CUT ALONG DOTTED LINEPower Supply/Chargers Operating GuideModels Include:ModelInput120VAC, 60HzOutputAuxiliary Power-LimitedOutput (unswitched)RippleV

Página 9 - PD8UL/PD8ULCB

- 2 - eFlow104N SeriesOverview:The eFlow104N power supply/chargers convert a 120VAC / 60Hz input to a 24VDC nominal output(see Power Supply Configura

Página 10 - - 10 - eFlow104N Series

eFlow104N Series - 3 -Specifications:Installation Instructions:Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA

Página 11

- 4 - eFlow104N Series9. Trigger terminals are end of a line resistor supervised (10k ohms). Opening or shorting trigger terminals will cause [

Página 12 - - 12 - eFlow104N Series

eFlow104N Series - 5 -Terminal Identification:Power Distribution ModuleTerminal LegendPD8UL/PD8ULCBTerminal LegendPD16W/PD16WCBFunction/Description1

Página 13 - A.2 Relays

- 6 - eFlow104N SeriesPower Distribution Module(s):Fig. 3a - PD8UL Power Distribution Board Fig. 3b - PD8ULCB - Power Distribution Board Power-Limi

Página 14 - - 14 - eFlow104N Series

eFlow104N Series - 7 -LGNNCCNONCCNOBAT FAILAC FAIL--- DC +ACAC1DC--- BAT +– AUX +TRIGGER EOLSUPERVISED5A 250VRESETGND NOdisableenable2 hr

Página 15 - IIeFlow104N Series J17M

- 8 - eFlow104N SeriesNEC Power-Limited Wiring Requirements for eFlow104N Models:Power-limited and non power-limited circuit wiring must remain separ

Página 16 - Overview:

eFlow104N Series - 9 -DoorWire Strap(fromEnclosureto Door)Battery & AC SupervisionCircuit (power-limited)LGNNCCNONCCNOBAT FAILAC FAIL--- DC +A