Altronix Sav9D Installation Instructions Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Acessórios para eletricidade Altronix Sav9D Installation Instructions. Altronix Sav9D Installation Instructions User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 12
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
DC CCTV Power Supplies
Installation Guide
Models Include:
Sav4D
- 12VDC @ 5 amp
- Four (4) Class 2 Rated PTC Protected Power-Limited Outputs.
Sav9D
- 12VDC @ 5 amp
- Nine (9) Class 2 Rated PTC Protected Power-Limited Outputs.
Sav18D
- 12VDC @ 5 amp
- Eighteen (18) Class 2 Rated PTC Protected Power-Limited Outputs.
Sav182D
- 12VDC @ 11 amp
- Eighteen (18) Class 2 Rated PTC Protected Power-Limited Outputs.
Sav36D
- 12VDC @ 11 amp
- Thirty-Six (36) Class 2 Rated PTC Protected Power-Limited Outputs
Rev. 070709 More than just power.™
Vista de página 0
1 2 3 4 5 6 ... 11 12

Resumo do Conteúdo

Página 1 - Installation Guide

DC CCTV Power SuppliesInstallation GuideModels Include:Sav4D- 12VDC @ 5 amp - Four (4) Class 2 Rated PTC Protected Power-Limited Outputs.Sav9D - 1

Página 2 - - 2 - Sav4/9/18/182/36D

- 10 - Sav4/9/18/182/36DWiring AC line cord for models SAV4D, SAV9D and SAV18D:1. Connect black lead to terminal marked [L]. Connect green lead to te

Página 3 - LED Identification:

Sav4/9/18/182/36D - 11 -Enclosure Dimensions for Sav4D, Sav9D and Sav18D:8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm)1.25”(31.75mm)1.25”(31.75mm)

Página 4 - Enclosure

- 12 - Sav4/9/18/182/36DAltronix is not responsible for any typographical errors. Product specifications are subject to change without notice.140 58th

Página 5

- 2 - Sav4/9/18/182/36DOverview:Altronix Sav Power Supplies provide 12VDC distributed via four (4), nine (9), eighteen (18), thirty-six (36)Class 2 R

Página 6

Sav4/9/18/182/36D - 3 - turn trimpot clockwise to increase voltage or counter clockwise to decrease voltage. Note: Voltage will be the same for al

Página 7 - Adjustment

- 4 - Sav4/9/18/182/36D The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the pres

Página 8

Sav4/9/18/182/36D - 5 -GreenLead115VAC, 60Hz/230VAC, 50Hz power mainsnon power-limitedClass 1Keep power-limited wiring separate from non power-limit

Página 9 - 7/8” Knockout

- 6 - Sav4/9/18/182/36DGreenLead115VAC, 60Hz/230VAC, 50Hz power mainsnon power-limitedClass 1Keep power-limited wiring separate from non power-limite

Página 10 - Green Lead

Sav4/9/18/182/36D - 7 -12VDC power outputs(For wiring utilizeknockouts on theleft hand sideof enclosure)Class 2 not wet, Class 3 wet,wiring to be us

Página 11 - Sav4/9/18/182/36D - 11

- 8 - Sav4/9/18/182/36D12VDC power outputs(For wiring utilizeknockouts on theleft hand sideof enclosure)Class 2 not wet, Class 3 wet,wiring to be use

Página 12 - - 12 - Sav4/9/18/182/36D

Sav4/9/18/182/36D - 9 -Installation Instructions for 3-wire Line Cord:Wiring methods shall be in accordance with the National Electrical Code/NFPA 7

Comentários a estes Manuais