Series
Access Power Controllers
Installation Guide
Models Include:
Rev. DF102512
Maximal11
- Power Supply 1:
12VDC @ 3.5 amp or 24VDC @ 2.7 amp.
- Power Supply 2:
12VDC @ 3.5 amp or 24VDC @ 2.7 amp.
- Sixteen (16) fuse protected
power-limited outputs.
Maximal33
- Power Supply 1:
12VDC @ 5.5 amp or 24VDC @ 5.7 amp.
- Power Supply 2:
12VDC @ 5.5 amp or 24VDC @ 5.7 amp.
- Sixteen (16) fuse protected
non power-limited outputs.
Maximal55
- Power Supply 1: 12VDC @ 9.5 amp.
- Power Supply 2: 12VDC @ 9.5 amp.
- Sixteen (16) fuse protected
non power-limited outputs.
Maximal77
- Power Supply 1: 24VDC @ 9.7 amp.
- Power Supply 2: 24VDC @ 9.7 amp.
- Sixteen (16) fuse protected
non power-limited outputs.
Maximal75
- Power Supply 1: 12VDC @ 9.5 amp.
- Power Supply 2: 24VDC @ 9.7 amp.
- Sixteen (16) fuse protected
non power-limited outputs.
More than just power.
TM
Altronix Corp.
140 58th St. Brooklyn, NY
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - Series

SeriesAccess Power ControllersInstallation GuideModels Include:Rev. DF102512Maximal11- Power Supply 1: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp.- Po

Página 2 - Table of Contents:

- 10 - Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused)+ DC –BAT FAIL NC C NO NC C NO + BAT ---

Página 3 - Altronix Corp

Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused) - 11 - Fig. 4Maximal772.5A 250V2.5A 250V2.5A 250V2.5A 250V2.5A 2

Página 4

- 12 - Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused)Fig. 5Maximal752.5A 250V2.5A 250V2.5A 250V2.5A 250V2.5A 2

Página 5

Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused) - 13 - NEC Power-Limited Wiring Requirements for Maximal11:Power

Página 6 - Maintenance:

- 14 - Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused)NEC Power-Limited Wiring Requirements for Maximal33 and M

Página 7

Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused) - 15 - NEC Power-Limited Wiring Requirements for Maximal77:Power

Página 8

- 16 - Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused)NEC Power-Limited Wiring Requirements for Maximal75:Power

Página 9 - Switch Detail

Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused) - 17 - ISOLATED POWER INPUT12 OR 24 VAC OR VDC(LOCK POWER) ISOLA

Página 10 - Maximal55

- 18 - Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused)1’7"4.00"2.00"6.25"0.85"1.00&quo

Página 11 - Maximal77

Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused) - 19 - Notes:

Página 12 - Maximal75

- 2 - Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused)Table of Contents:Maximal Series Overview ...

Página 13

- 20 - Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused)Altronix is not responsible for any typographical errors.

Página 14

Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused) - 3 - Maximal Series Overview:Maximal Access Power/Controllers d

Página 15

- 4 - Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused) Fire Alarm disconnect input trigger options: a) Normal

Página 16

Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused) - 5 - (b) Fail-Secure Switched Power outputs: For Fail-Sec

Página 17 - OUTPUT EOL

- 6 - Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused)Maintenance:Unit should be tested at least once a year for

Página 18 - Enclosure Dimensions:

Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused) - 7 - Power Supply Board Terminal Identification:Terminal Legend

Página 19

- 8 - Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused)Power Supply Board Stand-by Battery Specifications:Altroni

Página 20

Maximal11/Maximal33/Maximal55/Maximal77/Maximal75 Access Power Controllers (Fused) - 9 - NC NO C KEYPAD PUSH BUTTON ACCESS CONTROL PANEL OUTPUT REL