Rev. 030408
Active UTP Transceiver Hub
with Integral Isolated Camera Power
Installation Guide
Models Include:
HubWayLD8Di HubWayLD16Di
- UL Listed eight (8) Channel Active UTP - UL Listed sixteen (16) Channel Active UTP
Transceiver Hub with Integral Isolated Camera Power Transceiver Hub with Integral Isolated Camera Power
HubWayLD82Di HubWayLD162Di
- UL Listed eight (8) Channel Active UTP - UL Listed sixteen (16) Channel Active UTP
Transceiver Hub with Integral Isolated Camera Power Transceiver Hub with Integral Isolated Camera Power
- Includes eight (8) UL Listed Accessory - Includes sixteen (16) UL Listed Accessory
HubWayAv Video Balun/Combiners HubWayAv Video Balun/Combiners
HubWayLD83Di HubWayLD163Di
- UL Listed eight (8) Channel Active UTP - UL Listed sixteen (16) Channel Active UTP
Transceiver Hub with Integral Isolated Camera Power Transceiver Hub with Integral Isolated Camera Power
- Includes eight (8) UL Listed Accessory - Includes sixteen (16) UL Listed Accessory
HubWayDv Video Balun/Combiners HubWayDv Video Balun/Combiners
More than just power.
TM
Video • Data • Power
Vista de página 0
1 2 3 4 5 6 7 8

Resumo do Conteúdo

Página 1 - Installation Guide

Rev. 030408Active UTP Transceiver Hubwith Integral Isolated Camera PowerInstallation GuideModels Include:HubWayLD8Di HubWayLD16Di- UL Listed eight (8)

Página 2

- 2 - HubWayLD Active Isolated UnitOverview:Altronix HubWayLD8Di/16Di Active UTP Transceiver Hub w/Integral Isolated Camera Power transmits UTP video,

Página 3

HubWayLD Active Isolated Unit - 3 -4. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 5, pg. 7).5. Plug the ground

Página 4 - 115VAC 220VAC

- 4 - HubWayLD Active Isolated Unit1 2 3 4 CH 1-4 CH 5-8 28VAC OFF 24VAC + DATA -1-8+ DATA -9-165 6 7 8 9 10 11 12 CH 9-12 28VAC OFF 24VA

Página 5 - HubWayDv

HubWayLD Active Isolated Unit - 5 -1 - White/Orange [VIDEO +]2 - Orange [VIDEO -- ]3 - White/Green [DATA +]4 - Blue [AC 1]5 - White/Blue [AC 2]6 - Gre

Página 6 - Typical Applications:

- 6 - HubWayLD Active Isolated Unit115VACInput, 50/60HzVideoPowerVideoDataPowerVideoPowerHubWayDv/DviVideo BalunCombinerCAT-5CAT-5CAT-5FixedCameraFixe

Página 7 - TOP & BOTTOM

HubWayLD Active Isolated Unit - 7 -1.625" 8.5" .75" 19.125" 17.625" (ON) 16 PICTURE GAIN PICTURE GAIN PICTURE GAIN PICT

Página 8 - Wall Mount Installation

- 8 - HubWayLD Active Isolated Unit140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056website: www.altronix.com, e-mail: in